M L120
Specifications
Logging - Optional for L120 Enclosed Logger (Part #L120)
• 120 MB logging memory with fast Ethernet download
• Logging rates up to 500 samples per second
• Includes i2 Standard data analysis software (Pro Analysis upgrade available)
Inputs
• 2 Digital and 3 Speed inputs
Inputs - Optional (requires I/O upgrade)
• 6 analogue voltage inputs
4 x 0 to 5.46 V, 1.33 mV resolution
2 x 0 to 15.0 V, 3.66 mV resolution
• 2 analogue temperature inputs
0 to 15 V, 3.66 mV resolution
Outputs - Optional (requires I/O upgrade)
• 4 low side outputs PWM or switched operation
• 0.5 Amp max, current limited and thermal overload protected
Expanders
• Compatible with E816 and E888 expanders (providing full functional use)
Internal Sensors
• 3-axis accelerometer, detection range: +/-5G
• Temperature sensor
• Sensor supply voltage
• Battery voltage
Communications
• 2 configurable CAN buses, with individually programmable CAN bus speeds.
One can be used as RS232 Receive.
• 2 x RS232 ports
One with transmit and receive
One with receive only
Power supply
• Operating voltage: 6 to 32 V DC
• Operating current: 0.4 A typical at 14 V (excluding sensor currents)
• Reverse battery protection
• Battery transient protection
Sensor supply currents
• 5 V sensor supply: 0.25 A maximum
• 8 V sensor supply: 0.25 A maximum
Operating temperature
• Internal: -20 °C to 80 °C
• Typical ambient temperature range in free air: -20 °C to 65 °C
Physical
• Size: 134.5 x 103.9 x 20.2 mm excluding connector and tab
• Weight 310 g
• 1 x 34 pin waterproof connector
Please Contact Us for further information.